Mission Planner resets sensor readout rate etc. #611

Closed GoogleCodeExporter closed 9 years ago

GoogleCodeExporter commented 9 years ago
What steps will reproduce the problem?
1. Disable sensor readout (update rate 0 Hz)
2. Exit MP
3. Launch MP
4. Sensor readout is at 3 Hz again

This also happens sometimes when just using planner - rates suddenly revert 
(for example when viewing radio input in raw sensor view)

What is the expected output? What do you see instead?

Decreased bandwidth and all values stay set.

What version of the product are you using? On what operating system?

MP 1.1.74, Win7 64b

Please provide any additional information below.

This is important in case of low bandwidth link (APC220) because it can't keep 
up with 3Hz sensor readout (+1Hz everything else)

Original issue reported on code.google.com by zviratko...@gmail.com on 24 Apr 2012 at 7:57

GoogleCodeExporter commented 9 years ago
i have modified this in the next planenr version

Original comment by Meee...@gmail.com on 25 Apr 2012 at 8:35

GoogleCodeExporter commented 9 years ago

Original comment by Meee...@gmail.com on 3 May 2012 at 5:28