Hi, nice guide by the way!
We have a question about this item in the `Purchasing_List.xlsx`:
35 | Plastic scintillator | 1 | 5x5x1 cm Plastic scintillator | You want something that peaks i…
-
Hi!
I'm currently working with Gate9.3 and trying out Optical Simulation with Scintillation processes.
It's working fine thus far, except when I try to generate Optical Data with:
/gate/output/ro…
-
I've identified what I believe to be a fairly decent deal for a Nal(Ti) crystal, which is 25mmx25mm.
I'd want to be able to identify isotopes with a fair amount of certainty, but I cannot find any in…
-
Hi!
I'm currently working with Gate9.3 and trying out Optical Simulation with Scintillation processes.
It's working fine thus far, except when I try to generate Optical Data with:
/gate/output/ro…
-
Hi,
I'm not sure is this is a bug or not, but I'm posting this problem here. I'm trying to design a simple ECAL with PbWO4 crystals, using the CLIC calorimeter geometry. If I just use PbWO4 witho…
-
This is an experiment that Naomi and I used to work for. I think it might be nice to also include smaller experiments that mean something to us personally.
-
Strangely enough the crystal does cherenkov (exected) while it doesn't do scintillation, and the optic fiber doesn't do cherenkov.
-
Hi all,
I am trying to use dd4hep to do some studies on a crystal dual readout calorimeter. I successfully followed the installation instructions at https://dd4hep.web.cern.ch/dd4hep/page/installati…
-
When simulating GRIFFIN efficiency with SCEPTAR paddles present unexpected and unphysical efficiencies are observed above about 250 keV. Adding SCEPTAR increases amount of high energy gamma-rays depos…
-
[image](https://cloud.githubusercontent.com/assets/7471884/2995331/0f83e020-dcdc-11e3-8abf-d21b2a720609.png)
I'm making a theme in beta 3.But when I use "i" to force crash the window to see the log ea…