cheertsang commented 6 years ago

Run experiments without contact chamber to compare results with and without contact chamber.

Without Contact Chamber 5-9 to 5-10

5-11-18

cheertsang commented 6 years ago

Ran experiment for 22 hours without contact chamber.

5-9-18-headloss-control

Slope: 0.0006, Intercept: 25.647 cm Headloss increase of 12 cm over 22 hours.

cheertsang commented 6 years ago

Ran experiment for 15 Hours without Contact Chamber 5-12-18-headloss-control