temperature vs potential temperature #206

Open penguian opened 5 years ago

penguian commented 5 years ago

keyword_keepgit owner:inh599@nci.org.au type_defect | by inh599


CABLE utilises bulk aerodynamic representations for the sensible heat flux with the flux being proportional to differences in temperature. A more theoretically sound basis is for the flux to be proportional to differences in potential temperature (or even virtual potential temperature).

A methodology has been derived to implement this within CABLE - applying to both offline and coupled simulations - while retaining the existing structure of CABLE. Further detail in the accompanying documentation.


Issue migrated from trac:206 at 2023-11-27 11:27:20 +1100

penguian commented 5 years ago

@inh599@nci.org.au _uploaded file T_v_theta.pdf (204.3 KiB)_

documentation for Ticket 206

penguian commented 2 years ago

@inh599@nci.org.au changed owner from somebody to inh599

penguian commented 2 years ago

@inh599@nci.org.au changed milestone from 6. Report to 3. Implementation

penguian commented 2 years ago

@inh599@nci.org.au commented


I (Ian H) will finally get round to coding this up - ahead of preparation of the canopy code for JAC readiness.

penguian commented 2 years ago

@inh599@nci.org.au commented


Code has been prepared - introduces a new switch cable_user%use_pot_T_in_H which defaults to FALSE. Initial offline testing completed successfully. Benchcab testing being undertaken to ensure bitwise reproducibility with the trunk when swich is FALSE.

Results need further analysis - more comprehensive documentation (of benchmarking and with switch set to TRUE) to follow.

penguian commented 1 year ago

@ccc561@nci.org.au set keywords to keepgit