Closed isotc211 closed 1 year ago
ISO/TC 211 WG6, Imagery 2019-06-07 11:32:48 UTCCreated 0 Presentation to TC211 WG6 on errors in 19115-2
ISO/TC 211 Admin 2019-07-04 17:45:17 UTC Request 148 has been marked as a duplicate of this request.
This is mainly a summary of other work items related to the 19115-2 amendment. Work has been completed.
Justification summary of changes per previous issues
Proposal Corrigendum to ISO 19115-2:2019 to include: Align Data Dictionary Table B.4 Row 27 to UML Class Diagram Figure 2 Correct Definition and Range of Role name: sensor of MI_Instrument Add Data Dictionary Table B.16 Row 123.1 consistent with UML Class Diagram Figure 4 Add missing Role name: parameter of LE_Processing Remove XSD element content from mac:MI_Instrument_Type Remove XSD element sensor from mrc:MI_Band_Type Revise mrc.xml example instance document accordingly Restore XSD cit:CI_Date_Type.date to type gco:DateTime_PropertyType Add XML “convenience namespace” ‘gmi/2.0’ to ISO Standards Maintenance Portal (Note additional errata next slide)