Closed TimMcGue closed 9 months ago
Hi @TimMcGue thank you for this feedback and for providing detailed information. We'll review this and will let you know when the documentation is updated.
Hi @TimMcGue thanks again for raising this issue. Your feedback has now been addressed in the documentation. We have added a bullet to the "About this task" section to clarify that all steps in the procedure should be performed in the order: Switch_A_1, Switch_B_1, Switch_A_2, Switch_B_2 https://docs.netapp.com/us-en/ontap-metrocluster/maintain/task_upgrade_rcf_files_on_mcc_ip_switches.html#verify-that-the-rcf-file-is-supported
Looks perfect - thank you!
Page URL
https://docs.netapp.com/us-en/ontap-metrocluster/maintain/task_upgrade_rcf_files_on_mcc_ip_switches.html
Page title
Upgrade RCF files on MetroCluster IP switches
Summary
This step:
2 - Prepare the IP switches for the application of the new RCF files.
And this step:
3 - Download and install the IP RCF file, depending on your switch vendor.
Need to be done one switch at a time. However, this warning isn't shown until step #3.
Update the switches in the following order: Switch_A_1, Switch_B_1, Switch_A_2, Switch_B_2
Just by reading it is possible to misinterpret and perform step #2 on all switches and then do step #3 one switch at a time which would result in issues.
I'm not sure the best way to convey this detail. But basically you do this order: Switch_A_1 Step #2 and #3
Switch_B_1 Step #2 and #3
Switch_A_2 Step #2 and #3
Switch_B_2 Step #2 and #3
This section has a similar type back and forth at the bottom that might be good to mimic: https://docs.netapp.com/us-en/ontap-metrocluster/maintain/task_upgrade_firmware_on_mcc_ip_switches.html
Thanks as always for the great documentation!!
Public issues must not contain sensitive information