Pulse matched filtering places a boxcar filter upstream of the
averager and preamble detector. The filter length is equivalent
to the number of samples in one Mode S chip (0.5us). This
technique enhances operation when using sample rates > 4Msps.
rx_path.py now takes 'use_pmf', defaults to False
modes_rx has new CLI option '-p' or '--pmf' to turn on PMF
Pulse matched filtering places a boxcar filter upstream of the averager and preamble detector. The filter length is equivalent to the number of samples in one Mode S chip (0.5us). This technique enhances operation when using sample rates > 4Msps.