Closed DaveBenham closed 1 year ago
Interesting. I'll take a look.
Should be fixed; at high sample rates some the numbers get very small, and it would stop updating.
Great news. Thanks :)
On Sun, Feb 19, 2023 at 6:52 PM Matt Demanett @.***> wrote:
Should be fixed; at high sample rates some the numbers get very small, and it would stop updating.
— Reply to this email directly, view it on GitHub https://github.com/bogaudio/BogaudioModules/issues/221#issuecomment-1436135573, or unsubscribe https://github.com/notifications/unsubscribe-auth/AEHPDWPCXNPGR5DNL43QZ73WYKW3HANCNFSM6AAAAAAUQ4ZILM . You are receiving this because you authored the thread.Message ID: @.***>
As long as VCV sample rate is 48 kHz or below, then SLEW in slow mode seems to work just fine.
Bat at 96 kHz and SLEW in slow mode, rise / fall at 10 (100 s/V), and current voltage at 0 or 10 V, then a 10 volt change results in no change. For example, when applying a toggled 10V gate to the input.
With a VCV sample rate of 196 kHz and SLEW in slow mode, the output never moves, regardless what the input value is or the Rise / Fall setting.
Tested on both Windows and Mac. My VCV version is 2.1.2