Closed remmie1972 closed 2 years ago
Next time, please attach a log file. Copy/pasting mutilates the telegram.
The parser for telegrams looks at voltage per phase, to determine whether the meter is reporting 3-phase electricity. However, DSMR 4.2 isn't reporting voltage. I'll change the parser to check to power instead.
Hi Erik,
Thanks for the update! All 3 phases show up now. Great stuff!
Hi Erik,
Thanks for an awesome plugin ! However I'am having a little trouble with it. In the closed issues there is a topic about 3 phase P1 meters. I have a 3 phase installation and the Eve app only shows a single current value, not split into L1, L2 and L3. Could it be a setting? the config of the homebridge P1-plugin is below :
{ "dsmr22": false, "name": "P1", "outlet": false, "serialPort": "/dev/ttyUSB0", "timeout": 60, "platform": "P1" },
Also in the closed topic you requested a log of homebridge running in debug mode (-D). hereby that log : in the log I can make out the separate currents and powers for all 3 phases. But still the Eve app does not show all 3, just a single current/power. For information : I also have solar panels so the power back values will be used. I guess that is obvious from consumption back T1 and T2 values in the log though :)
[08/01/2022, 00:02:59] [P1] raw data: {"type":"KFM5KAIFA-METER", "checksum":"EF9E", "version":"4.2", "lastupdated":"2022-01-08T00:02:26", "id":"E0026000030985316", "consumption_t1":24575.366, "consumption_t2":13445.403, "consumption_back_t1":5595.177, "consumption_back_t2":14397.615, "tariff":1, "power":712, "power_back":0, "failures_short":3, "failures_long":1, "log":{"2017-03-26T04:38:04":11313,"2000-01-01T00:00:01":2147483647}, "l1_sags":0, "l2_sags":1, "l3_sags":1, "l1_swells":0, "l2_swells":0, "l3_swells":0, "msg_num":"", "msg_text":"", "l1_current":2, "l2_current":0, "l3_current":1, "l1_power":400, "l2_power":127, "l3_power":194, "l1_power_back":0, "l2_power_back":0, "l3_power_back":0 }
[08/01/2022, 00:02:59] [P1] telegram: KFM5KAIFA-METER
1-3:0.2.8(42) 0-0:1.0.0(220108000226W) 0-0:96.1.1(4530303236303030303330393835333136) 1-0:1.8.1(024575.366kWh) 1-0:1.8.2(013445.403kWh) 1-0:2.8.1(005595.177kWh) 1-0:2.8.2(014397.615kWh) 0-0:96.14.0(0001) 1-0:1.7.0(00.712kW) 1-0:2.7.0(00.000kW) 0-0:96.7.21(00003) 0-0:96.7.9(00001) 1-0:99.97.0(2)(0-0:96.7.19)(170326043804S)(0000011313s)(000101000001W)(2147483647s) 1-0:32.32.0(00000) 1-0:52.32.0(00001) 1-0:72.32.0(00001) 1-0:32.36.0(00000) 1-0:52.36.0(00000) 1-0:72.36.0(00000) 0-0:96.13.1() 0-0:96.13.0() 1-0:31.7.0(002A) 1-0:51.7.0(000A) 1-0:71.7.0(001A) 1-0:21.7.0(00.400kW) 1-0:41.7.0(00.127kW) 1-0:61.7.0(00.194kW) 1-0:22.7.0(00.000kW) 1-0:42.7.0(00.000kW) 1-0:62.7.0(00.000*kW) !EF9E