Open inducer opened 2 months ago
@anderson2981 reports a 1D shock tube case meshed with structured tensor products that should obey $u(x,y)=U(x)$ for the life of the simulation, but it does not.
comparing pressure and temperature on 2 neighboring rows of cells. note the magnitude difference when moving to p5
p4 after 1000 steps
p5 after 1000 steps
@anderson2981 reports a 1D shock tube case meshed with structured tensor products that should obey $u(x,y)=U(x)$ for the life of the simulation, but it does not.