Closed AlBla84140 closed 4 weeks ago
Hello, I have no idea. I guess there a round value in the Card to keep small display. So sad you don't respect the issue template, I would be able to check your configuration and the power configured.
Désolé pour ces erreurs de communication et le doublon. Je pense que vous voulez le dev du thermostat. Ci dessous le dev de mon thermostat.
hvac_modes:
- heat
- "off"
min_temp: 7
max_temp: 35
target_temp_step: 0.1
friendly_name: Thermostat Virtuel SdE
supported_features: 401
current_temperature: 23.2
temperature: 19.5
hvac_action: idle
preset_modes:
- none
- frost
- eco
- comfort
- boost
preset_mode: eco
is_on: true
hvac_mode: heat
type: null
is_controlled_by_central_mode: false
last_central_mode: null
frost_temp: 9.5
eco_temp: 19.5
boost_temp: 26
comfort_temp: 22.5
frost_away_temp: 0
eco_away_temp: 0
boost_away_temp: 0
comfort_away_temp: 0
power_temp: null
target_temperature_step: 0.1
ext_current_temperature: 21.39
ac_mode: false
current_power: null
current_power_max: null
saved_preset_mode: eco
saved_target_temp: 26.3
saved_hvac_mode: null
motion_sensor_entity_id: null
motion_state: null
power_sensor_entity_id: null
max_power_sensor_entity_id: null
overpowering_state: null
presence_sensor_entity_id: null
presence_state: null
window_state: "off"
window_auto_state: "off"
window_bypass_state: false
window_sensor_entity_id: null
window_delay_sec: null
window_auto_enabled: false
window_auto_open_threshold: null
window_auto_close_threshold: null
window_auto_max_duration: null
window_action: window_turn_off
security_delay_min: 60
security_min_on_percent: 0.5
security_default_on_percent: 0.1
last_temperature_datetime: "2024-10-16T22:17:12.300483+02:00"
last_ext_temperature_datetime: "2024-10-16T22:17:12.300483+02:00"
security_state: false
minimal_activation_delay_sec: 30
device_power: 0.75
mean_cycle_power: 0
total_energy: 12.44
last_update_datetime: "2024-10-16T22:17:12.305937+02:00"
timezone: Europe/Paris
temperature_unit: °C
is_device_active: false
ema_temp: 23.2
is_used_by_central_boiler: false
is_over_switch: true
is_inversed: false
keep_alive_sec: 0
underlying_switch_0: switch.sde_m_a
underlying_switch_1: null
underlying_switch_2: null
underlying_switch_3: null
on_percent: 0
power_percent: 0
on_time_sec: 0
off_time_sec: 600
cycle_min: 10
function: tpi
tpi_coef_int: 0.6
tpi_coef_ext: 0.01
You have a configured power of device_power: 0.75
I think this is rounded to 1 kW in the card to reduce the place.
In your post, the heater don't heat and the power is correctly set to 0:
mean_cycle_power: 0
power_percent: 0
So I guess all is normal.
Bonjour et merci pour votre travail. Lorsque l'on a oublié de paramétrer la puissance du convecteur, il reste à 1 kW. Si on installe une carte Thermostat versatile, il est indiqué 1Kw. Si on revient sur le paramétrage de la puissance du convecteur dans le service, par exemple 0.75 KW, dans la carte il reste toujours indiqué 1 KW, alors que dans le dev le "mean_cycle_power: 0.75" et le "device_power: 0.75" sont bien à 0,75 KW Pourquoi ?