networkupstools / nut-ddl

Network UPS Tools Devices Dumps Library
http://networkupstools.org/ddl/index.html#_supported_devices
4 stars 16 forks source link

Create INELT__Monolith_E1000LT-12V__nutdrv-qx__2.7.4__01.dev #9

Closed RangerPCW closed 5 years ago

zykh commented 5 years ago

Thanks, @RangerPCW -- could you also add the info from upscmd and upsrw, please?

Also, for the commit message, we usually use a format like this: "Add \ \ @ \", e.g., for this device, it should ideally be something like "Add INELT Monolith E1000LT-12V @ 2.7.4".

zykh commented 5 years ago

(I'm half asleep, and didn't notice this before) For future reference, this is the same as https://alioth-lists.debian.net/pipermail/nut-upsuser/2019-March/011341.html

RangerPCW commented 5 years ago

Thanks, @RangerPCW -- could you also add the info from upscmd and upsrw, please?

Yes, I can upload these files March 25-26.

RangerPCW commented 5 years ago

upscmd -l inelt-boiler

Instant commands supported on UPS [inelt-boiler]:

beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.toggle - Toggle the UPS beeper bypass.start - Put the UPS in bypass mode bypass.stop - Take the UPS out of bypass mode load.off - Turn off the load immediately load.on - Turn on the load immediately shutdown.return - Turn off the load and return when power is back shutdown.stayoff - Turn off the load and remain off shutdown.stop - Stop a shutdown in progress test.battery.start - Start a battery test test.battery.start.deep - Start a deep battery test test.battery.start.quick - Start a quick battery test test.battery.stop - Stop the battery test

RangerPCW commented 5 years ago

upsrw inelt-boiler

[battery.energysave] Switch off when running on battery and no/low load Type: ENUM Option: "no" SELECTED Option: "yes"

[battery.packs] Number of battery packs Type: RANGE Option: "1-99" SELECTED

[battery.protection] Prevent deep discharge of battery Type: ENUM Option: "no" Option: "yes" SELECTED

[input.frequency.high] Maximum input line frequency (Hz) Type: RANGE Option: "53-60" SELECTED

[input.frequency.low] Minimum input line frequency (Hz) Type: RANGE Option: "40-47" SELECTED

[input.transfer.high] High voltage transfer point (V) Type: RANGE Option: "237-254" SELECTED

[input.transfer.low] Low voltage transfer point (V) Type: RANGE Option: "206-223" SELECTED

[ups.delay.shutdown] Interval to wait after shutdown with delay command (seconds) Type: RANGE Option: "12-5940" SELECTED

[ups.delay.start] Interval to wait before (re)starting the load (seconds) Type: RANGE Option: "0-599940" SELECTED

[ups.start.auto] UPS starts when mains is (re)applied Type: ENUM Option: "no" Option: "yes" SELECTED

[ups.start.battery] Allow to start UPS from battery Type: ENUM Option: "no" Option: "yes" SELECTED