Closed denizci88 closed 2 years ago
You are correct these are deprecated sentences. These are emitted to address the requirement to support legacy equipment and will likely be removed in future versions DPT and DBT sentences are also emitted.
Thank you for your reply. DPT and DBT are still in the standard.
Hello,
First of all thank you for this great tool. I would like to inform about an issue. I have reviewed the NMEA sentences and found two sentences, as follows.
$SDDBK,44.9,f,13.7,M,7.5,F17 $SDDBS,44.9,f,13.7,M,7.5,F0F
When I checked IEC 61162-1 standard, I noticed that DBK and DBS are not available. Hopefully, you don't consider my message as a negative comment, and would accept it as a support to your great tool. Thank you again.