Goose Trigger Event Code Box #19

Closed slactjohnson closed 5 months ago

slactjohnson commented 6 months ago

Dring thinks it might be useful to have a configurable goose trigger event code entry box. This way the laser group could set up a goose rate on any valid event code. The goose trigger button would then read the event code from the configuration box and apply that event code.

slactjohnson commented 6 months ago

I can see how this is more convenient in some ways, but it doesn't fit nicely in with how we do configurations now. I'd like to see how the laser group feels about the current setup after using it for a while before doing this.

slactjohnson commented 5 months ago

Now that we're moving towards the combo box style configuration, this would be fairly easy to do. However, I think that the operators may appreciate the clarity of the drop down menu from a combo box, so if we provide sufficient configurations they may be happier with that. Still going to wait and see.