Closed rufik closed 3 years ago
Hi @rufik, welcome!
LT DA 08 I would go with ALTHERMA(LT_DA_04-08KW).h
!
Happy installation!
@rufik, is it ok with you? If so, you can close this issue :)
I've just collected all stuff needed and I'm gonna install & run this weekend - so let this issue be opened 2-3 days more please. I'll be back with feedback 😉
It looks like it's working quite fine, so let's close this issue right now 😁 I'm gonna take a closer look into values...
Just for the records - all attrs from this EHVH:
{
"*Refrigerant type": "Conv 802 not avail.",
"Override CMD:0x00 N_INV=1": "Conv 996 not avail.",
"Override CMD:0x00 N_STD=0": "Conv 996 not avail.",
"Override CMD:0x00 N_FAN=2": "Conv 996 not avail.",
"Override CMD:0x00 N_EV=2": "Conv 996 not avail.",
"Override CMD:0x00 N_20S=1": "Conv 996 not avail.",
"Override CMD:0x00 N_CH=1": "Conv 996 not avail.",
"Override CMD:0x00 N_SV=3": "Conv 996 not avail.",
"Sensor Data Qty": "0",
"INV compressor Qty": "0",
"STD compressor Qty": "0",
"Fan Data Qty": "0",
"Expansion Valve Data Qty": "0",
"4 Way Valve Data Qty": "0",
"Crank Case Heater Qty": "0",
"Solenoid valve Qty": "0",
"Max. connectable indoor units": "0",
"Connected Indoor Unit Qty": "0",
"O/U MPU ID (xx)": "0",
"O/U MPU ID (yy)": "0",
"O/U capacity (kW)": "0",
"NextDataGrid": "Conv 995 not avail.",
"In-Out separator": "Conv 998 not avail.",
"Override All Clear": "Conv 996 not avail.",
"Operation Mode": "Heating",
"Thermostat ON/OFF": "ON",
"Restart standby": "OFF",
"Startup Control": "OFF",
"Defrost Operation": "OFF",
"Oil Return Operation": "OFF",
"Pressure equalizing operation": "OFF",
"Demand Signal": "OFF",
"Low noise control": "OFF",
"Error type": "Warning",
"Error Code": "AH",
"Target Evap. Temp.": "21.0938",
"Target Cond. Temp.": "0",
"Discharge Temp. Drop": "OFF",
"Discharge Temp. Protection Retry Qty": "Conv 310 not avail.",
"Comp. INV Current Drop": "OFF",
"Comp. INV Current Protection Retry Qty": "Conv 311 not avail.",
"HP Drop Control": "OFF",
"HP Protection Retry Qty": "Conv 310 not avail.",
"LP Drop Control": "OFF",
"LP Protection Retry Qty": "Conv 311 not avail.",
"Fin Temp. Drop Control": "OFF",
"Fin Temp. Protection Retry Qty": "Conv 310 not avail.",
"Other Drop Control": "OFF",
"Not in use": "46080",
"O/U EEPROM (1st digit)": "Conv 215 not avail.",
"O/U EEPROM (3rd 4th digit)": "Conv 215 not avail.",
"O/U EEPROM (5th 6th digit)": "Conv 215 not avail.",
"O/U EEPROM (7th 8th digit)": "Conv 215 not avail.",
"O/U EEPROM (10th digit)": "Conv 215 not avail.",
"O/U EEPROM (11th digit)": "Conv 214 not avail.",
"Outdoor air temp.(R1T)": "-2.5",
"O/U Heat Exch. Temp.": "0",
"Discharge pipe temp.": "48",
"Suction pipe temp.": "0",
"Heat exchanger mid-temp.": "-8",
"Liquid pipe temp.(R6T)": "0",
"Heat sink temp.": "2.5",
"Pressure sensor": "0",
"Pressure sensor(T)": "Conv 405 not avail.",
"INV primary current (A)": "7.3",
"INV secondary current (A)": "7.3",
"Voltage (N-phase) (V)": "230",
"Brine Flow Switch": "OFF",
"Brine inlet temp.": "-8",
"Brine outlet temp.": "0",
"Refrig. temp. evap. In": "0",
"Refrig. temp. evap.Out": "0",
"INV frequency (rps)": "56",
"INV frequency 2 (rps)": "68",
"STD Compressor 1": "OFF",
"STD Compressor 2": "OFF",
"Fan 1 (10 rpm)": "56",
"Fan 2 (step)": "68",
"Expansion valve (pls)": "17464",
"Expansion valve 2 (pls)": "11008",
"Expansion valve 3 (pls)": "1",
"Expansion valve 4 (pls)": "0",
"Expansion valve 5 (pls)": "0",
"4 Way Valve 1": "OFF",
"4 Way Valve 2": "OFF",
"4 Way Valve 3": "ON",
"4 Way Valve 4": "ON",
"4 Way Valve 5": "ON",
"Crank case heater 1": "OFF",
"Crank case heater 2": "OFF",
"Crank case heater 3": "ON",
"Crank case heater 4": "ON",
"Solenoid Valve 1": "OFF",
"Solenoid Valve 2": "OFF",
"Solenoid Valve 3": "ON",
"Solenoid Valve 4": "ON",
"Solenoid Valve 5": "ON",
"Data Enable/Disable": "ON",
"Indoor Unit Address": "0",
"I/U operation mode": "Heating",
"Freeze Protection": "OFF",
"Silent Mode": "ON",
"Freeze Protection for water piping": "OFF",
"Error detailed code": "0",
"I/U capacity code": "Conv 219 not avail.",
"DHW setpoint": "45",
"LW setpoint (main)": "29.9",
"Water flow switch": "ON",
"Thermal protector (Q1L) BUH": "ON",
"Thermal protector BSH": "ON",
"Benefit kWh rate power supply": "OFF",
"Solar input": "OFF",
"Bivalent Operation": "OFF",
"2way valve(On:Heat_Off:Cool)": "OFF",
"3way valve(On:DHW_Off:Space)": "OFF",
"BSH": "OFF",
"BUH Step1": "OFF",
"BUH Step2": "OFF",
"BPH": "OFF",
"Water pump operation": "ON",
"Solar pump operation": "OFF",
"Indoor Option Code": "19",
"I/U Software ID (xx)": "Conv 215 not avail.",
"I/U Software ID (yy)": "Conv 215 not avail.",
"I/U EEPROM Ver.": "0",
"Leaving water temp. before BUH (R1T)": "29.1",
"Leaving water temp. after BUH (R2T)": "29.5",
"Refrig. Temp. liquid side (R3T)": "25.7",
"Inlet water temp.(R4T)": "25",
"DHW tank temp. (R5T)": "58.6",
"Indoor ambient temp. (R1T)": "22",
"Ext. indoor ambient sensor (R6T)": "0",
"Reheat ON/OFF": "ON",
"Storage eco ON/OFF": "OFF",
"Storage comfort ON/OFF": "OFF",
"Powerful DHW Operation. ON/OFF": "OFF",
"Space heating Operation ON/OFF": "ON",
"System OFF (ON:System off)": "OFF",
"Emergency (indoor) active/not active": "OFF",
"LW setpoint (add)": "45.4",
"RT setpoint": "22.5",
"Add. Ext. RT Input Cool.": "OFF",
"Add. Ext. RT Input Heat.": "OFF",
"Main RT Cooling": "OFF",
"Main RT Heating": "OFF",
"Pwr consumption limit 4": "OFF",
"Pwr consumption limit 3": "OFF",
"Pwr consumption limit 2": "OFF",
"Pwr consumption limit 1": "OFF",
"None": "OFF",
"Tank preheat ON/OFF": "OFF",
"Circulation pump operation": "OFF",
"Alarm output": "OFF",
"Space H Operation output": "ON",
"Flow sensor (l/min)": "19.2",
"Water pressure": "1.8",
"Water pump signal (0:max-100:stop)": "4",
"[Future] 3 way Valve Mixing 1": "0",
"[Future] 3 way Valve Mixing 2": "0",
"I/U EEPROM (3rd digit)": "Conv 215 not avail.",
"I/U EEPROM (4th 5th digit)": "Conv 215 not avail.",
"I/U EEPROM (6th 7th digit)": "Conv 215 not avail.",
"I/U EEPROM (8th 9th digit)": "Conv 215 not avail.",
"I/U EEPROM (11th digit)": "Conv 215 not avail.",
"I/U EEPROM (12th digit)(rev.)": "Conv 214 not avail.",
"Hybrid Op. Mode": "H/P only",
"Boiler Operation Demand": "OFF",
"Boiler DHW Demand": "OFF",
"Bypass Valve Output": "ON",
"BE_COP": "0",
"Hybrid Heating Target Temp.": "0",
"Boiler Heating Target Temp.": "29.9",
"Add pump": "OFF",
"Main pump": "OFF",
"Mixed water temp.": "0",
"2nd Domestic hot water temperature": "59.1",
"Target delta T heating": "4",
"Target delta T cooling": "5"
}
Heating is on (undefloor type), weather dependant, Madoka indoor thermostat. A lot of information :)
HI @rufik,
Do you have connect your ESP on the X9 port ? Seem's I have same Heat Pump, but I haven't any X10 port, the X9 was a blue one.
Thank in advance for your replie.
It's X10A at mine, see pics attached.
Hi,
Thanks for your quick reply.
Seems to be a old PCB board. Mine was more little, so I have to check wich one have RX and TX.
Best regards
De : Rufik @.> Envoyé : vendredi 14 octobre 2022 05:41 À : raomin/ESPAltherma @.> Cc : Renouveaux @.>; Comment @.> Objet : Re: [raomin/ESPAltherma] Definition file for Altherma 3 LT EHVH-D6V (#31)
It's X10A at mine, see pics attached. [IMG_20210303_181712__01-01]https://user-images.githubusercontent.com/425558/195770720-ab072c02-ff9a-4a1d-b5b9-80a6eb8e93aa.jpeg [IMG_20210316_135325-01]https://user-images.githubusercontent.com/425558/195770729-6fd460cc-891c-45e6-bb99-d6a35d9ca312.jpeg
— Reply to this email directly, view it on GitHubhttps://github.com/raomin/ESPAltherma/issues/31#issuecomment-1278510574, or unsubscribehttps://github.com/notifications/unsubscribe-auth/ABZ3NARZIC54SRTSEYXWHZLWDDW7HANCNFSM4YQ2VXWA. You are receiving this because you commented.Message ID: @.***>
Seems to be a old PCB board. Mine was more little, so I have to check wich one have RX and TX. Best regards https://user-images.githubusercontent.com/7583362/195792996-da5ecde6-c724-4391-9608-f349ecf2998c.png
Isn't it board attached to front case with LCD screen? If yes, it's not that board you're looking for :) The proper board is behind the shield AFAIR, on the main unit.
Oh, ok, I will open my unit to see what's inside. Because yes, you are right, I'm looking on the part with LCD screen.
Thanks a lot for your time
I have new Altherma 3 LT model EHVH08S18DA6V and I'd like to try ESPAltherma with HA :) So I haven't found any information which definition file is most suitable for my model?