Itho Daalderop Amber Heat pump integration
Home Assistant integration for Itho Daalderop Amber heat pump.
The Amber heat pump family contains 3 models.
- 65 (6,5Kw)
- 95 (9,5Kw)
- 120 (12Kw)
Although only tested with the Amber 95. It should work fine with the other two models.
The Itho Daalderop Amber is produced in Asia for the West European market.
Using a WIN CE as a controller with a custom version of the Heatstar software.
Although there are models/brands using the same controller it is not advisible
to use this integration with other than the three Itho Amber models.
Because of the custom version of the Heatstar software.
And
doing so can cause damage to your heat pump.
Sensor Updates
After changing a sensor value, it can take up sometime (poling time) before it updates.
Modbus
This integration uses the external Modbus connection on the back of the LCD controller.
com3, connections 7 (RS485B) & 8 (RS485A).
Hardware
For this Home Assistant integration, the RS485 serial Modbus connection must be converted to Modbus TCP/IP.
This can be done with standard of shelf modbus RTU RS485 to TCP/IP gateways.
Waveshare as example, has afordable gateways.
Please make sure you order the right one that supports Modbus TCP, because not all do!
It is possible to use a Raspberry Pi 2 or higer as gateway with
this software.
Installation
HACS Custom Repository
On the HACS main page, hit the triple dots menu upper right corner.
click on custom repositories and add https://github.com/remmob/itho_amber as URL
the category must be integration. Click add to save.
Manual
Copy the itho_amber
folder in the custom_components
folder into your Home Assistant config/custom_components
folder.
After rebooting Home Assistant, this integration can be configured through the integration setup UI.
Settings
Modbus settings
Serial: [\<waveshare>gateway]
- Baudrate: 19200 k/bits
- Databits: 8
- stopbit: 1
- flow control: none
- parity: none
TCP/IP: [\<waveshare>gateway]
- Device IP: \<IP-address of your (Waveshare) gateway>
- Subnet mask: \<depends on your network settings (default: 255.255.255.0)>
- Device & destination port: \<default-port: 502>
- workmode: \<TCP server>
- device web port: \<80>
- gateway: \<IP-address-your-router>
- multihost settings protocol: \<Modbus TCP to RTU>
Integration:
- prefix: used for the entity names. (default: amber)
example: sensor.amber_ambient_temperture_ta
- IP-address: \<IP-address of your gateway>
- port: \<default-port: 502>
- polling time: \<default: 10 seconds>
Known issues
- The first V2.29 software, released in 5-2024 contains a bug.
When a Modbus value is written, the days when the legionella program
runs, get altered.
This is known tot Itho and will be resolved in the next update.
Please contact your installer for information about and how to get the software updates.
- Settings M1.01, M1.20 and M9.05 have different bandwidth in the Modbus
than through the LCD controller.
For example: M1.01 can be set in the LCD between 1-5°C, in the Modbus
between 1-3°C. When set above 3°C in the LCD, will display correctly in the integration
When you set it to 5 in the integration, it reverts back to max 3°C.
- Some values are read-only. I do not understand why this choice was made by
Itho, I have asked them
to make all settings writeable... To be continued...
Roadmap
- Adding error codes
- Weekly clocks\timers. They can not be written. Timers with automations
in Home Assistant makes much more sense.