victronenergy / venus

Victron Energy Unix/Linux OS
https://github.com/victronenergy/venus/wiki
592 stars 75 forks source link

Cerbo audible alarm not working? #740

Closed mpvader closed 3 years ago

mpvader commented 4 years ago

https://community.victronenergy.com/questions/68678/cerbo-gx-internal-audible-alarm-not-working.html

mkrenzke commented 4 years ago

I'd assume it is not a (general) hardware issue since the buzzer should be part of the test procedure. But I will double check it actually is.

mkrenzke commented 4 years ago

Pedro just confirmed: Testing the buzzer is part of the test plan.

mpvader commented 4 years ago

It was already double checked to be an issue on at least two Cerbos. (Guy his Cerbo, and this customers Cerbo).

@mansr pls check if you can reproduce or not.

mansr commented 4 years ago

Configuring a digital input as "door alarm" works as expected on my Cerbo with v2.62~4.

Wholistic commented 4 years ago

The alarm does make some sound, but it is extremely quiet.

This is an audio recording of the alarm, over the background sound of the Multiplus-II fan. It is not possible to hear the alarm (to my ear) in the same room as the multiplus fan.

It looks like the alarm is about 6khz - and you can see when the alarm is sounding (with mic pressed up to the unit), it barely registers over the background fan noise. At 1M, it no longer registers.

https://www.dropbox.com/s/2rftnw4oc3kh08m/cerbo%20gx%20alarm.mov?dl=0

jhofstee commented 3 years ago

included in the next v2.70~