w4mmp / MSCC-PW

1 stars 1 forks source link

AM Carrier Level setting not maintained after MSCC-PW restart. #16

Closed Bob-TX closed 2 years ago

Bob-TX commented 2 years ago

Describe the bug The AM Carrier Level setting on the Rx/Tx tab is not saved and restored during MSCC-PW exit/stop and re-start.

To Reproduce Steps to reproduce the behavior:

  1. Run MSCC-PW. Click Rx/Tx tab and observe AM Carrier Level setting is centered at 50%.
  2. Click on AM Carrier Level adjustment and change setting to a different setting (25% used in this example).
  3. Click on Main tab and then Rx/Tx tab and observe AM Carrier Level adjustment shows chosen previous setting (25% in this example).
  4. Click on Main tab and then click on EXT and choose STOP to close MSCC-PW.
  5. Run MSCC-PW. Click Rx/Tx tab and observe AM Carrier Level setting is centered at 50%.

Expected behavior I expected whatever setting I choose for AM Carrier Level would be saved and restored after MSCC-PW was exited/stopped and then re-started.

MSCC-PW release date (please complete the following information): MSCC 09/07/2022

Desktop (please complete the following information):

w4mmp commented 2 years ago

Hi Bob, I will be working on your issues in the coming week. 73, Ron

w4mmp commented 2 years ago

This issue has been resolved. New release on the Google Drive: MSCC-PW-Install-20220919.exe 73, Ron