Hello Martin,
I am very interested in you plugin. Could you please tell me what line is the modbus address of the inverter please ?
Because I think this is the reason why it is not working here…
jfh75 updated
2 months ago
-
### Describe the bug
The plugin was working beautifully, then last week suddenly wouldn't connect with error: unrecognized inverter type - serial number : unknown.
The IP address hasn't changed, t…
-
### Describe the bug
Add integration -> Select Interface:Serial, Inverter type: growatt or any other -> Serial Interface Parameters: Submit
![crash](https://github.com/user-attachments/assets/0126…
-
**Describe the bug**
When Predbat tries to set charging time, the last step "charge_end_minute" fails to update.
It also appears in the log file that "charge_end_minute" returns the value of "char…
-
### Describe the bug
With new I removed the integration first, upgraded the solax-modbus from HACS and rebooted the raspberry PI. Now I cannot add it again and I get "unknown error," on the screen t…
-
### Describe the bug
installed and something is working but the data seems very odd. Looks like registers are read wrongly.
See pic attached, esp if you compare Phase 1,2,3
### Integration Ver…
-
### Describe the bug
In a parallel system when you send the remotecontrol values to the master inverter it also applies them to the slave inverter.
The problem is the power limit values allowed are …
-
### Describe the bug
The grid and PV energy meters shown on the configuration page (when experimental features are turned on) both show 100 times the correct value. E.g., here for total solar energy…
-
I have a LAN data logger, serial number 19XXXXXXX, firmware version ME-121001-V1.0.6(202011261020).
This does not have port 8899 open. Instead port 30003 is open. I have tried a register scan on th…
-
### Describe the bug
Intermittently, the integration will stop and all the entities will zero out. Reloading the integration _usually_ seems to fix it, so it sounds like a HA/integration issue as opp…