### Describe the problem
Venus OS shows a Voltage High alarm everyday, I guess caused by the SOC reset feature.
Is this normal behavior or do I have wrong settings applied?
### Driver version
…
-
Hello,
First of all, thanks for your project.
I tried to use it through bluetooth (bt) but it does not connect. I assume it is due to bt password. Indeed, when I try to connect with my PC to the…
-
### Describe the problem
Hello,
I have been running the driver for a long time on a Daly BMS with a 100 Ah battery made of 16 Lifepo4 cells.
I updated the driver to the current version v1.2.2…
-
### Describe the bug
I noticed that sometimes dbus-serialbattery reports very low or high single cell voltage, affecting SOC calculation and general state of the system.
To diagnose the problem I ma…
-
Hi @syssi,
I tried both the old and ant_bms platform without success. I got an old custom components working with : https://pastebin.com/0bBPx33L
Maybe you can see the difference with your cur…
-
### Describe the problem
My Multiplus II doesn't go into float mode. (bulk to absorption only).
Serial-Battery shows "Float (linear mode)" in Venus OS under JKBMS => Parameters
As you can see in …
-
Hello,
I would like to leave only my test with the **ANT 32S 300A** .
I had some difficulty communicating with the BMS.
Through another topic I noticed that pins A, B is not RS485
I tested jus…
-
Describe the issue here.
If you experience bluetooth connection problems, follow these steps before opening an issue:
https://github.com/fl4p/batmon-ha#troubleshooting
* Include exact BMS model n…
-
I would like to ask, if you could support for switching on / off the FETs from ANT BMS?
With the bluetooth , i can turn them on or off with the app.
Id like to disconnect the whole battery on lo…
-
### Describe the bug
Hello All,
This is not per say a bug, maybe i'm doing something wrong.
My cells are well balanced and i do not charge them all the way up, i keep at 54.65V Bulk and 54.4 Fl…