## overview
Calibrating the 15-50ml conical rack smashes the pipette into the rack. The dimensions of the container definition appear to be off as the initial guess is about a centimeter too far …
-
Hi,
Is there any possibility to make the code independent from hardware platform (ESP chip)? I am about to built system based on Arduinos as let me say protocol converters and RPi with Domotics as us…
-
## overview
To build #861 (View attached pipettes in tip probe), the app needs to be able to compare an RPC pipette (which is effectively just a mirror of an API `Pipette` object) with the response…
mcous updated
6 years ago
-
## overview
Pipettes are commissioned with a model string written to their onboard memory:
```
p300_single_v1
```
This model is returned by the API for certain calls, e.g. `GET /pipettes`. …
mcous updated
6 years ago
-
I just noticed the following:
Today, the heating engineer did some maintaing on my heating. He removed the optolink adapter for an hour or so. I have a Raspberry Pi running that requests some data …
-
Here is a deviation between `--explicitcallregs` and the old scheme. It's about tail-recursive call.
A fragment from the old scheme, `gcc.cpplib._cpp_init_internal_pragmas` for ARM:
```
[...]
…
-
P300S stopped dropping tips
## Expected Behavior
Pipette plunger should travel low enough to drop tips
## Observed Behavior
Pipette plunger not traveling low enough to drop tips
## Steps to…
-
Hi,
I was wondering why a vcf file is not being recognised by the variant effect predictor model ? if I use bed file, then I am only getting the probability matrix and not e-value and effect (log2…
-
Hi.
Fantastic tool. Exactly what I needed.
Is there a way to supply the correct filepath to the github binder link produced by the nbsphinx prologue?
As specified here:
https://github.…
-
## Problem
I'm currently able to use an external trigger to send a marker in my OpenBCI EEG data. However, when trying to use this with the lab streaming layer, it doesn't work.
## Expected
…