21:58:28.811 -> SCD40::begin: got serial number 0x98EA5F073B62
21:58:29.332 -> Periodic measurement is disabled!
21:58:29.332 -> Temperature offset is currently: 5.00
21:58:29.332 -> Temperatu…
-
### Describe the problem/bug
Installed SCD4x dependency and connected[ Seeed SCD41 Sensor](https://wiki.seeedstudio.com/Grove-CO2_%26_Temperature_%26_Humidity_Sensor-SCD41/). Sensor is detected but…
-
I am requesting a driver for `SCD4x`.
### Device description
The SCD4x is Sensirion’s next generation miniature CO2 sensor that offers an unmatched price-to-performance ratio. Tape and reel pack…
-
We are seeing the sensor returning 0x0000 for CO2 and error 0x0004 for the selt-test, what can be the cause? And what is error 4 ?
-
The current CO2 sensor, [SCD30](https://www.sensirion.com/en/environmental-sensors/carbon-dioxide-sensors/carbon-dioxide-sensors-scd30/), has two calibration modes: Auto Calibration (ASC) and Forced R…
-
A big way to drive the cost of the Frog down is to design a custom circuit board that contains some of the electronics, instead of buying multiple dev boards. We should explore this option :)