Closed penguian closed 6 years ago
@martin.dix@anu.edu.au changed component from ACCESS model
to ACCESS-CM2
@martin.dix@anu.edu.au commented
In app/um/rose-app.conf
follow setup of AMIP runs and use
STASHMSTR=.
In app/coupled/rose-app.conf
create a link with
[file:$ATM_RUNDIR/STASHmaster_A]
mode=symlink
source=$CYLC_TASK_WORK_DIR/STASHmaster_A
See latest version of u-ao854.
@martin.dix@anu.edu.au changed _comment0 which not transferred by tractive
@martin.dix@anu.edu.au changed status from new
to closed
@martin.dix@anu.edu.au set resolution to fixed
resolution_fixed
| by jxs599@nci.org.auIn the standard suite u-ap748, reconfiguration fails looking for user added STASHmaster_A (error message below). app/um/rose-app.conf has been modified to include "STASHmstr=.." rather than standard AMIP modification "STASHmstr=." as appropriate for model run. However inconsistent with reconfiguration.
QuickFix - artiicially copied to work/XXXX/ and re-triggered.
A better fix may be approriate.
Error message: Error opening STASHmaster file:../STASHmaster_A : ? file not found, unit 10, file /short/p66/jxs599/cylc-run/au-aa644/work/00010101T0000Z/recon/../STASHmaster_A ? Error from processor: 0
Issue migrated from trac:336 at 2024-01-31 18:31:25 +1100