CICE restarts written at every time step in the final coupling time step #28

Open kieranricardo opened 1 month ago

kieranricardo commented 1 month ago

CICE restarts are written at every timestep in the final coupling time step, with a coupling tilmestep of 1hr and a CICE time step of 450s 8 CICE restarts are being written every month.

MartinDix commented 1 week ago

Related to https://github.com/COSIMA/access-om3/issues/175?