Open eacmills opened 1 year ago
Log Name: 2022-11-12_1835_22B-193 Project: 22B-193 SBID(s): 42958526 EBID(s): 42987381 Observing Date: 12-Nov-2022 Observation Type: Science Bands Used: X K No. Subarrays: 1 Observer(PI): Prof Elisabeth Mills Source File(s): 22B-193_sb42958526_1_1 Operator(s): Hannah Brower Array Configuration: C Decommissioned Antenna: 20
Adobe PDF version of this log is located at: http://www.vla.nrao.edu/operators/logs/
WEATHER INFORMATION
Time(UTC) Dew Pt Temp Wind Bar Press API RMS Phase(degs) 12Nov 18:36:13 -7.8 7.3 W at 3.3 m/s 788.8 6.0 12Nov 20:00:10 -7.8 9.3 S at 3.2 m/s 787.5 9.1 12Nov 22:00:08 -9.7 8.9 E at 6.7 m/s 786.8 8.9
Operator comments for the above weather entries
12Nov 18:36:13 Sky clear.
12Nov 20:00:10 Sky clear.
12Nov 22:00:08 Sky clear.
COMMENTS AND OUTAGES
Outage information format: Start Time, End Time, Category, Form#, # Antennas, Down Time(minutes) Antenna ID(s) and Data Effect Description
Number of Antennas Used: 27
12Nov 18:35:35 Starting project 22B-193.
12Nov 18:35:35 The band(s) used is(are): X K.
12Nov 18:36:02 On source 1331+305=3C286 with all available antennas.
12Nov 18:35:35 To access your data from the NRAO archive visit: https://science.nrao.edu/facilities/vla/archive All VLA science data are processed through the VLA calibration pipeline. Details are at: https://science.nrao.edu/facilities/vla/data-processing/pipeline For further questions please use the NRAO Helpdesk at: https://science.nrao.edu/observing/helpdesk Adobe PDF version of this log is located at: http://www.vla.nrao.edu/operators/logs/
12Nov 18:35:35 Note: To support our ongoing RFI monitoring efforts, any feedback from your program on RFI can be sent to: nrao-rfi@nrao.edu The key information to provide is:
12Nov 18:35:35 12Nov 22:05:02 LO-IF WO-15533 1.00 209.5 Antenna(s) 12 (Data: Lost): LO module down, antenna parked
12Nov 18:35:35 12Nov 22:05:02 SERVO WO-15524 1.00 209.5 Antenna(s) 16 (Data: Lost): Elevation motor errors, antenna parked
12Nov 18:35:35 12Nov 22:05:02 SERVO WO-15539 1.00 209.5 Antenna(s) 07 (Data: Lost): Azimuth CB faults, antenna parked
12Nov 18:35:35 12Nov 22:05:02 CRYOGENICS WO-15535 0.89 185.4 Antenna(s) 06 (Data: Corrupted): Compressor issues, K band receiver warm. Data may be weak
Project End Time Total Time % Down Time Total Down Time (minutes x 27 ants) (minutes)
12-Nov-2022 22:05:02 5655.2 14.4% 813.7
Pipeline issues noted by staff:
ea05 gain amplitude solutions show a split about half way through the observation.
ea14 gain amplitude solutions are low for a few scans.
ea17 gain ampliutde solutions are very high for a few scans.
ea26 gain amplitude solutions are low for some scans.
The complex gain calibrator shows decorrelation, primarily from scan='2,33~50,54,59,63~69,73'.
Issues noted but not flagged by staff
ea05 gain amplitude solutions show a split about half way through the observation.
ea14 gain amplitude solutions are low for a few scans.
ea17 gain ampliutde solutions are very high for a few scans.
ea26 has some low gain amplitudes for some scans.
The complex gain calibrator shows decorrelation, primarily from scan='2,33~50,54,59,63~69,73'. [?]
Other issues
SB 42958526 JACKS region 4
Product Links