Removed read only check for UART status registers
#31
Closed
Jiss-Jose
closed
2 years ago
Jiss-Jose
commented
2 years ago
UART status register bits can change based on UART activity irrespective of test write check which can lead to false failures
Currently test is making sure that no exception during write to RO registers
Signed-off-by: jisjos01
jiss.jose@arm.com