Closed dhwalters423 closed 5 years ago
@dhwalters423 @alphatronicstva please, have a look at this thread.
Hope that could help.
Caused by the difference between RF0 and RF module. RF module is the one shipped with the IDB05A1 shield and works as expected.
Reported by @alphatronicstva - Mbed Cloud customer. Internal Ref: IOTPAN-60
Background Information Mbed OS 5.7.5
Description Custom designed hardware, based on the STM32 F429ZI, with an SPBTLE-RF0 module soldered directly on the board. They have successfully ported this to work with their board.
Using the BLE Heart Rate monitoring application: https://github.com/ARMmbed/mbed-os-example-ble/blob/master/BLE_HeartRate reporting frequent disconnects and instability.
Connects sometimes, very unstable and disconnects after some time automatically.
100% reproducibility from the customer.