Battery measurements with the current system and charge controller measure charging voltage and not battery voltage.
✔️ Expected Behavior
Charge controller sometimes have 3 ports.
Solar Panel
Battery
Load
The Load port usually separates charging voltage coming from the solar panels.
This allows for a more accurate measurement of the battery voltage and the possibility of also measuring charge voltage separately.
❌ Actual Behavior
The current charge controller has no dedicated load port meaning measurements are made directly on the battery. The voltage is then raised whenever the system is charging resulting in only being able to measure the charging voltage.
Lake Profiler Version
1.03.31
Area(s) with issue?
Buoy
Steps to reproduce
Battery measurements with the current system and charge controller measure charging voltage and not battery voltage.
✔️ Expected Behavior
Charge controller sometimes have 3 ports.
The
Load
port usually separates charging voltage coming from the solar panels.This allows for a more accurate measurement of the battery voltage and the possibility of also measuring charge voltage separately.
❌ Actual Behavior
The current charge controller has no dedicated load port meaning measurements are made directly on the battery. The voltage is then raised whenever the system is charging resulting in only being able to measure the charging voltage.