Parameter estimation for complex physical problems often suffers from finding ‘solutions’ that are not physically realistic. The PEUQSE software provides tools for finding physically realistic parameter estimates, graphs of the parameter estimate positions within parameter space, and plots of the final simulation results.
For the cantera case, it is very very confusing because the units are supposed to be mol/m^2, but I tend to use mol/cm^2
Surface site density: 2.72E-9 mol/cm**2
For the cantera case, it is very very confusing because the units are supposed to be mol/m^2, but I tend to use mol/cm^2 Surface site density: 2.72E-9 mol/cm**2
Looking in this directory: https://github.com/AdityaSavara/PEUQSE/tree/master/PEUQSE/simulationDriver I mentioned the units issue in this file which was for the CTI: 191201Instructions.docx
And in this file I noted that I need to add comments to the yaml file about the units: 220519ProcDocForYAMLConversion.docx