Open Lauren-Wisbrock opened 4 months ago
We got 206 working, the display board cable was partially detached from opening it. Re-imaged card, working on GPS lock now.
When closing GONets the camera cable needs to be routed so that it does not go on top of the GPS antenna.
206 Update 07/22 Got stuck in imaging cycle, would not turn off manually, could not connect to control center. Left to die on its own in the lab 07/23 Plugged in to charge to full, was not powered on. 07/24 GONet powered on, screen was illuminated, never showed Adler logo screen or status screen after 10 min. Red shut off button was pressed and GONet turned off just a few seconds later. Collin opened the case to see if anything was loose, tightened one screw that was halfway unscrewed (the one by the yellow button) Case seems looser than the others, back screws are not flush/tight and one is crooked.