AguaClara / String-Digester

5 stars 2 forks source link

String (theory) Prototype flow tests #18

Closed jillianwhiting closed 6 years ago

jillianwhiting commented 6 years ago

Tests to be conducted

  1. Varying flow rate
  2. Varying string spacing
  3. Varying anchoring points
jillianwhiting commented 6 years ago

Comments from preliminary test to make sure water flowed down the strings:

jillianwhiting commented 6 years ago

First tests were varying flow rate:

jillianwhiting commented 6 years ago

1st string spacing test (26 wraps) flow went only on strings

rosiekrasnoff commented 6 years ago

testing for spacing: we performed the same test of observing the flow while dosing from the pump and reduced the number of strings in the system to see the maximum spacing possible before flow stops following strings and filter would fail. 26 strings - flow stays on strings 20 strings - flow stays on strings 15 strings - flow stays on strings 10 strings at 70 rpm - flow goes along strings but sometimes falls off the string partway down 10 strings at 35 rpm - flow stays on strings 8 strings at 35 rpm - flow stays on strings 6 strings at 35 rpm - flow stays on strings -6 strings with water on full flow - flow still stays on strings, we notice webbing between two of the strings but all water flows on the strings down to the basin, none of the water doesn't make it onto a string.

rosiekrasnoff commented 6 years ago

continued testing: 5 strings at 35 rpm - flow stays on strings 3 strings at 25 rpm - flow stays on strings 1 string in the middle at 20 rpm - flow stays on strings 1 string in the corner at 20 rpm - flow stays on strings flow was increased and stayed on the string until about 60 rpm, at which point the system failed and the water didn't follow the strings.