Prefab sed tanks would not need such a strong frame if they had tension rods running through the tank. This can be accomplished with the cross members used to support the plate settlers. However, the cross members must be removable to insert the inlet manifold. Use pipe unions so that the cross pipes can be removed.
Prefab sed tanks would not need such a strong frame if they had tension rods running through the tank. This can be accomplished with the cross members used to support the plate settlers. However, the cross members must be removable to insert the inlet manifold. Use pipe unions so that the cross pipes can be removed.