First Meeting: 4:30-5:30 PM February 15th, 2018

YeonjinYun commented 6 years ago

Calculate the residence time in the contact chamber -> 127 seconds Maybe longer residence time in the contact chamber? How? Change the dimension! (bigger radius or longer tube) Calculate coagulant dose and change it to 1.00mg/L and check the effluent turbidity, if the turbidity is higher, then change the coagulant dose to find the ideal dose Compare results without waiting for floc blanket to form Therefore, make a sedimentation tank smaller version to speed up the process of forming floc blanket

cheertsang commented 6 years ago

Removed sedimentation tank, changed influent turbidity to 100 NTU