AguaClara / float_valve

High Flow Float Valve
0 stars 0 forks source link

New slider pipe design #43

Open FelixYuHengYang opened 6 years ago

FelixYuHengYang commented 6 years ago

@monroews @ethan92429

Hi,

HFFV has found a new way to design hole patterns so that it would effectively make designing hole patterns very simple and consistent as opposed to arbitrary. However, it would decrease the range that it would be effective, working over the top third of the distribution tank rather than the top half. Would that be a tradeoff too costly to consider redesign?

monroews commented 6 years ago

Shutting down flow over the top third of the tank would be fine.