Investigate the optimal coagulant dosage at different humic acid concentrations
1 stars 11 forks source link

No flow through clay pump (meeting w/ Monroe) #8

Closed pjm326 closed 6 years ago

pjm326 commented 6 years ago

ProCoDa was turning the clay pump up to max speed with no clear change in turbidity.

pjm326 commented 6 years ago

Meeting with Monroe about clay pump: Suggested cleaning out clay bucket as well as switching to the use of DI-water for the clay solution. Micro-tubing possibly too long and reaches too high.

pjm326 commented 6 years ago

Solved: Elevate clay pump and shorten micro-tubing. Have had no issues since the fix