AguaClara / ram_pump

Optimizing the hydraulic ram pump for more efficient use in providing plant plumbing.
4 stars 8 forks source link

Run Experiments with Pulley System #47

Closed cheertsang closed 5 years ago

cheertsang commented 5 years ago
cheertsang commented 5 years ago

Both buckets on the floor should be almost full when head tank above is empty. When water in head tank reaches line marked, throttle valve pumping water up to head tank. This should keep the water level in the sump pump bucket so that the intake is submerged. Overflow pipe from head tank should be draining slowly, keeping water in head tank at a constant level.

cheertsang commented 5 years ago

Add relay box to turn on/off sump pump, control with ProCoDA. (Like setting up mixer)

ChingPangggg commented 5 years ago

Run experiments after replacing string with wire. Opened all valves. Close valve at bottom of ram pump. Start sump pump. Throttle valve from sump pump to head tank. When water level reaches line in head tank, turn off sump pump.

Changed out scale.

98.6 g, 87.4 g, 82.4 g, 81.4 g

ChingPangggg commented 5 years ago

2/28/2019 84.7 g, 102.5 g 84.0 g, 86.5 g Measurements have been inconsistent and we are suspecting that this is because how the wire is bendable

ChingPangggg commented 5 years ago

displacement of plate; closed from top of threads: 3.5 cm open: 3.0 cm

mass of plate and hook: 24.9 g