Height of drive pipe: 1.74 m Height of drive pipe + water level in head tank: 2.06 m diameter of drive pipe: 23.65 mm
initial water level 6 cm from top of air chamber initial pressure in air chamber: 698.97 cm final water level 5 cm from top of air chamber
The volume of water pumped per 1 cycle is 0.5519 milliliter The theoretical time period in which water is being pumped into the air chamber is 0.08193 second The theoretical amount of water pumped is: 40.91 milliliter
similar to previous results Markdown file
Meeting with Monroe buy new pressure sensors, one that allows for higher pressures redo pulley system tests to figure out what spring we need
figure out setup for EPA
EPA Grant Proposal:
Lab:
EPA Grant Proposal:
EPA Conference:
Lab:
EPA Grant Proposal:
Lab:
Other:
[x] Verify terminal velocity by experimentation (terminal velocity found in Spring 2018 = .349 m/s)
[x] Calculate theoretical water pumped
[x] Fix code for experimental calculations
[x] Calculations to find efficiency (actual/theoretical)
[ ] Experiment with different parameters of experimentation (time of opening/closing valve)
[x] Look at graphs at point where waste valve pressure goes above the air chamber pressure
[x] Put pressure sensor closer to the effluent valve
[ ] Account for air in tubing from air chamber