AguaClara / ram_pump

Optimizing the hydraulic ram pump for more efficient use in providing plant plumbing.
4 stars 8 forks source link

Fabrication of new ram pump #71

Closed ChingPangggg closed 5 years ago

ChingPangggg commented 5 years ago

@monroews We are not sure about what to buy for fabrication of a new ram pump.

  1. First of all, for the rod that we needed to fabricate on our own, are we buying a fully threaded rod and then cut it down?
  2. For the design that involve pipe union, should we get a threaded T-joint, and a brass or PVC pipe union ?
ChingPangggg commented 5 years ago

@monroews And is this what we should order? https://www.mcmaster.com/9162k476

monroews commented 5 years ago

COnsider meeting with Paul Charles to see if he would have a recommendation for an easier way to fabricate the rod. We previously purchased a threaded rod and then cut it down. The union looks good. You can probably get a threaded Tee and short pipe nipples to connect between T and check valves. You will also need nipples to connect union to check valves.

ChingPangggg commented 5 years ago

Also, since we now want the effluent to be 1" pipe size, we will need to fabricate a new air chamber, and then use an elbow to connect the air chamber with the check valve. Is this correct?

monroews commented 5 years ago

Draw a sketch and that will make it clear what pieces you need.

ChingPangggg commented 5 years ago

Tapping hole for pressure sensor on T-joint: Drill bit: 7/16 Tap: 1/4in- 18 (or 16?)