Closed 0jay closed 5 years ago
try to reboot to see if is working
I did reboot at the time. No effect.
can you check if you gave this file /sbin/status-led-eventing.lua ?
Can’t you just stop the leds using /etc/init.d/ledfw stop?
The point is, mate, that the gui feature is non functioning on the TG799
On Tue, 9 Oct 2018 at 12:25 pm, Kevdagoat notifications@github.com wrote:
Can’t you just stop the leds using /etc/init.d/ledfw stop?
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428029070, or mute the thread https://github.com/notifications/unsubscribe-auth/AoSCUcDVqRz-t-ORORphf0wDi5vUz1-uks5ui_sEgaJpZM4XLQDy .
I know. It is a suggestion to replace ansuels script with that command
On 9 Oct 2018, at 9:36 am, Oscar James notifications@github.com wrote:
The point is, mate, that the gui feature is non functioning on the TG799
On Tue, 9 Oct 2018 at 12:25 pm, Kevdagoat notifications@github.com wrote:
Can’t you just stop the leds using /etc/init.d/ledfw stop?
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428029070, or mute the thread https://github.com/notifications/unsubscribe-auth/AoSCUcDVqRz-t-ORORphf0wDi5vUz1-uks5ui_sEgaJpZM4XLQDy .
— You are receiving this because you commented. Reply to this email directly, view it on GitHub, or mute the thread.
ok
On Tue, 9 Oct 2018 at 12:41 pm, Kevdagoat notifications@github.com wrote:
I know. It is a suggestion to replace ansuels script with that command
On 9 Oct 2018, at 9:36 am, Oscar James notifications@github.com wrote:
The point is, mate, that the gui feature is non functioning on the TG799
On Tue, 9 Oct 2018 at 12:25 pm, Kevdagoat notifications@github.com wrote:
Can’t you just stop the leds using /etc/init.d/ledfw stop?
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub < https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428029070 , or mute the thread < https://github.com/notifications/unsubscribe-auth/AoSCUcDVqRz-t-ORORphf0wDi5vUz1-uks5ui_sEgaJpZM4XLQDy
.
— You are receiving this because you commented. Reply to this email directly, view it on GitHub, or mute the thread.
— You are receiving this because you authored the thread. Reply to this email directly, view it on GitHub https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428031589, or mute the thread https://github.com/notifications/unsubscribe-auth/AoSCUY2sTNGRjCWd4CkdQkhQomruD9R_ks5ui_69gaJpZM4XLQDy .
Still waiting if the file exists.... Ledfw restart broke the led system entirely
I’m not at home mate, will have to wait till next week, sorry
TG799 GUI Version [ 8.8.62 ] running as double NAT (80.0.1.138).
For reference:
Technicolor TG789(i)vac. Power and Reset switches not shown.
Telstra Gateway Max (TG799vac). Power, Reset, WPS and DECT switches not shown.
Telstra T-Gateway (TG797nV3)
Front panel of TG800vac Telstra Gateway Max 2, DJN2130 Telstra Frontier Gateway or DJA0230 Telstra Smart Modem (Bottom to top: USB slot (USB2 on TG800), and Reset, Power, Pair and Wifi switches - top three also with leds.)
Top panel of DJN2130 Telstra Frontier Gateway or DJA0230 Telstra Smart Modem. Note TG800vac Telstra Gateway Max 2 has same panel with no sim Backup/Signal led.
Note: Detailed examination of TG799 shows Status has green, red and blue leds, Internet, WPS and DECT have green and red leds and other leds are single green leds.
@flywire can you check if you have the file?
also i need the log with logread
problem fixed
/sbin/status-led-eventing.lua exists.
Which log file? Syslog is disabled by default.
this file /sbin/status-led-eventing.lua exist?
Sorry, swiped wrong path.
I see logread generates output. What do you want?
i already fixed the problem about eco led... i hust need to know if that file is present on your modem
https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428107479
/sbin/status-led-eventing.lua exists [on my modem].
Maybe Internal server error is a different issue?
what is your timeout value?
What is command to retrieve?
from the gui eco page
default - 5000
update to latest build..
Then can you try to reboot and switch the eco led option on and off anche check if something change to the led?
https://github.com/Ansuel/tch-nginx-gui/issues/264#issuecomment-428102932
TG799 GUI Version [ 8.8.62 ] running as double NAT (80.0.1.138).
Rebooted - same error.
@flywire update, don't need to reboot this time
GUI Version [ 8.8.64 ] - No errors but all leds are green.
Do I need to wait 5000 (sec(?))?
5000 ms = 5 sec
eco led off --> save
eco led on --> save
Any difference?
No difference - waited 15 sec and checked between each.
BTW Running vnstat with internet, ethernet and led on usb constantly flickering.
can you give me the output of this command?
ps | grep status
/sbin$ ps | grep status
1329 root 6148 S {status-led-even} /usr/bin/lua /sbin/status-led-even
13633 root 1888 S grep status
uci show ledfw
/sbin$ uci show ledfw
ledfw.internet=service
ledfw.internet.check='1'
ledfw.iptv=service
ledfw.iptv.check='1'
ledfw.iptv.itf='iptv'
ledfw.voip=service
ledfw.voip.check='1'
ledfw.timeout=timeout
ledfw.timeout.ms='5000'
ledfw.syslog=syslog
ledfw.syslog.trace='0'
ledfw.status_led=status_led
ledfw.status_led.enable='1'
give me this file /etc/ledfw/statemachines.lua
emailed
ok so the problem is that statemachines doesn't have support for status at all...
let's check if the framework supports it
cat /usr/lib/lua/ledframework/ledhelper.lua | grep is_status_led_enabled
/etc/ledfw$ cat /usr/lib/lua/ledframework/ledhelper.lua | grep is_status_led_enabled -- @function [parent=#ledhelper] is_status_led_enabled function M.is_status_led_enabled()
ok good
update to latest dev gui and try the switch....
if it doesn't work reboot and retry also tell me if all the leds works properly
Tested as above - all leds always green.
Can leds be controlled with UCI? Do you want direct access to modem (through double nat)?
try with latest dev (and reboot after upgrade)
Status - Red; Wan, Internet, Ethernet - Green; other leds off; status or wifi button does nothing.
BTW - What does setting first three Eco Settings to on do?
DGA4130, Bridge Mode, 8.8.61-stable
Can't find ECO/CPU settings anymore. Do i have to restart the modem after GUI upgrade? I already cleared the browser cache but i still can't find it...
they are now i a separate card
they are now i a separate card
I understand but i don't have this card in bridge mode... I can only see the 10 old cards.
will unlock that card for bridge mode
Thanks!
@flywire i need this directory /usr/lib/lua/ledframework
@Ansuel 8.8.67-stable hasn't fixed the missing ECO card in bridge mode yet...
i need this directory /usr/lib/lua/ledframework
Assume email received 13 hours ago.
I don't expect this could be functional on a TG800 as there are only three switches with leds (power, pair [wps] and wifi). No leds would imply unit off.
Certainly don't want to press power switch.
@Kherby done sorry @flywire will check email anyway also the dga4132 don't have the info button.. we don't need the button, as it's only used to deacivate is for n ms (the timeout option)
@flywire i need file from /rom/usr/lib/lua/ledframework (latest dev overwrite them so.... the zip you send me is useless, if i'm wrong send them anyway i notice something strange in the file you sent)
Device Model: TG799vac Gui Version: 8.8.56
Description of problem: Eco LED settings has no effect