Open Kakihara83 opened 3 years ago
Will need to check. It may be that the structure RV export is only intended for load bearing floors. @WawanSolihin can you comment?
In the structural exchange requirements the slab will be exported as an aggregate of IfcBuildingElementParts, each for each material layer. Do you see the aggregation of the IfcBuildingElementParts? Attached is the example what expected in the Structural Exchange Requirement.
Seems it works with a simple multi layer as you said, It's not working creating structural deck using ifc4 structural exchange (i'm using rvt 2021 and exporter 21.2.1.0)
It will be helpful if you can send us a test model that has this issue so that we can investigate.
Project1-IFC4-Strucural.zip Here is a simple project created from basic structural template and autodesk family.... with both ifc "exported"
If i create for example a metal deck floor with a single element and 2 material layer and try to export it with Ifc4 Reference view [Structural] the floor will not exported. If i try to export instead with Ifc4 Reference view [Architecture] it will export fine, same with ifc 2x3....
Seems a Bug? What are the difference from Architecture and Structure ifc4 RV?
thank you