The scan_id is intended to be changeable by the Bluesky user. To maintain a unique ID, it would be necessary to supply custom handling that would prevent the user from changing or resetting the scan_id. An alternative is to connect the scan_id with an EPICS PV but, still, that would not guarantee a unique scan_id.
The
scan_id
is intended to be changeable by the Bluesky user. To maintain a unique ID, it would be necessary to supply custom handling that would prevent the user from changing or resetting thescan_id
. An alternative is to connect thescan_id
with an EPICS PV but, still, that would not guarantee a uniquescan_id
.The scan
uid
is the truly unique value.