BHTOM-Team / bhtom2

7 stars 2 forks source link

CPCS big sigma fix apply and re-calibrate 3 months of data #185

Open wyrzykow opened 3 months ago

wyrzykow commented 3 months ago

In CPCS/calibStepBody,

image

we need to change big sigma to be sig*1/np.sqrt(n_points), instead of +. The new code is already on git/ devCPCS.

This should fix stupid calibrations we still see, e.g. https://bh-tom2.astrolabs.pl/dataproducts/data/197658/ where r band is standardised to U.

This fix needs re-calibrating 3 months of data.

wyrzykow commented 6 days ago

The change has already been present in prod for a while now. However, the data should be re-calibrated, together with issue #213 . It means we need to recalibrate data starting mid-May 2024.