I found in our projects some AR-records, where I have no real clue, what they are for. Does it stand for absolute reference? Do we have to take them into account?

Please note, that F 0 and L record do not match.

$Comp
L MAX11207 U801
U 1 1 5694C9EB
P 4550 2900
AR Path="/566470F4/5694C6CE/5694C9EB" Ref="U801"  Part="1" 
AR Path="/566470F4/56951F6F/5694C9EB" Ref="U1201"  Part="1" 
AR Path="/566470F4/5694F8C8/5694C9EB" Ref="U901"  Part="1" 
AR Path="/566470F4/56950977/5694C9EB" Ref="U1001"  Part="1" 
AR Path="/566470F4/5695097C/5694C9EB" Ref="U1101"  Part="1" 
AR Path="/566470F4/56951F74/5694C9EB" Ref="U1301"  Part="1" 
AR Path="/566470F4/56951F79/5694C9EB" Ref="U1401"  Part="1" 
AR Path="/566470F4/56951F7E/5694C9EB" Ref="U1501"  Part="1" 
F 0 "U1501" H 4250 2300 60  0000 C CNN
F 1 "MAX11207" H 4150 2200 60  0000 C CNN
F 2 "standardSMD:QSOP-16_3.9x4.9mm_Pitch0.635mm" H 4550 3100 60  0001 C CNN
F 3 "" H 4550 3100 60  0000 C CNN
F 4 "MAX11207" H 4550 3100 60  0001 C CNN "InternalName"
    1    4550 2900
    1    0    0    -1  
$EndComp
$Comp
KarlZeilhofer commented 6 years ago

I think, the AR-records gives a schematic with multiple instances of one and the same sub-sheet the ability to annotate the multi-unit-parts in the different instances with different References and Units.

KiCad shows here a further inconsistency in the naming of things.

In AR Path="/566470F4/5694C6CE/5694C9EB" Ref="U801" Part="1" the Part is actually the number of the used Unit, e.g. one of 4 OP-amps within one package.