BYU-MicrostructureOfMaterials / OpenXY

Other
35 stars 14 forks source link

Running OpenXY #41

Open Daoud93 opened 6 months ago

Daoud93 commented 6 months ago

Hello,

I am trying to run openXY, and when I select the scan file (.ang ), I get the following message: " No matching grain files were found. Would you like to manually select a grain file?" when I press yes and I select the type 1 grain file, the selected scan file is gone, and I have to select the scan file again, and the same thing happens again. The same thing happens when I try to select the finest image ( I select OIM map.up2 format ). I would appreciate your immediate response and help.

image

Screenshot 2024-02-29 173438

![Uploading image.png…]()

dtfullwood commented 6 months ago

Try clicking 'No' and letting OpenXY find the grains. Maybe it's an issue with the UP format, which hardly anyone uses.

Daoud93 commented 6 months ago

I Clicked "No," and the same problem occurred. although the type 1 and type 2 grain files are present in the same directory

I Clicked "No," and the same problem occurred. although the type 1 and type 2 grain files are present in the same directory

dtfullwood commented 6 months ago

One suggestion is to not have file names with spaces in them. This is probably not an issue, but I'm not sure. Your folder name also is odd - ending in a hyphen. It sounds like it is having issues with your files. I thought you said it was a up2 format, but you have selected an ang file. You can email me directly on dfullwood@byu.edu.

Daoud93 commented 6 months ago

"> One suggestion is to not have file names with spaces in them. This is probably not an issue, but I'm not sure. Your folder name also is odd - ending in a hyphen. It sounds like it is having issues with your files. I thought you said it was a up2 format, but you have selected an ang file. You can email me directly on dfullwood@byu.edu.

Thank you very much for your response. For the "Select Scan File" option, I selected a scan file (.ang), and then a small window popped up asking me to select the grain file manually because no matching grain file was found. When I select the grain file iget an error. For the "Select Image File" option, I selected the .up2 file, and I got an error also. below a screenshot of the error I get on Matlab when I tru run openXY

image

dtfullwood commented 6 months ago

there is an issue with the scan size / number of scan points. I take it you have done a hexagonal scan rather than a square scan (square scan is preferred). I suggest you email me directly rather than working through the Github interface, and maybe we can set up a time to zoom later or something.

Daoud93 commented 6 months ago

there is an issue with the scan size / number of scan points. I take it you have done a hexagonal scan rather than a square scan (square scan is preferred). I suggest you email me directly rather than working through the Github interface, and maybe we can set up a time to zoom later or something.

Thank you very much. I will email you

Daoud93 commented 6 months ago

there is an issue with the scan size / number of scan points. I take it you have done a hexagonal scan rather than a square scan (square scan is preferred). I suggest you email me directly rather than working through the Github interface, and maybe we can set up a time to zoom later or something.

I sent you an email. Thank you very much