In the paper alfa_ka, the temperature coefficient for kappa, parameter seems to have a unit of [mS/m/K] however in the Comsol model given here its unit is [S/m/K]. We think the unit reported in the paper ( [mS/m/K] ) seems to be more likely. However, it is not clear which unit the results shown in the paper belongs to. You may find the exact line of code reporting [S/m/K] unit here:
In the paper
alfa_ka
, the temperature coefficient for kappa, parameter seems to have a unit of[mS/m/K]
however in the Comsol model given here its unit is[S/m/K]
. We think the unit reported in the paper ([mS/m/K]
) seems to be more likely. However, it is not clear which unit the results shown in the paper belongs to. You may find the exact line of code reporting[S/m/K]
unit here:https://github.com/Battery-Intelligence-Lab/multiscale-coupling/blob/dba3649f2eeb4228d2849e4d4e748c91ed6ad7a4/Battery_model.m#L53