BeFlE / SoMoSe

Soil Moisture Sensor
21 stars 6 forks source link

Standby Mode v3.4 #19

Open user20240627 opened 5 months ago

user20240627 commented 5 months ago

Hi,

in the datasheet for hardware v3.4 is specified a standby current of ~16uA.

My question is how to enter this state? Command 0x4C drops the current only to ~800uA.

BeFlE commented 5 months ago

Hi,

the standby current of 16 uA can only be reached with the latest firmware version (SoMoSe v3- FW version 1.4).

The currently sold lot is still with version 1.3.

An update must therefore be performed. You can do this with the help of an ESP32 and my SoMoSe firmware or send me the sensors and I will do it for you.

Best regards Christian

poker-spt commented 4 months ago

@BeFlE Could you please provide the firmware version 1.4 for the ESP32-C6 hardware?

Which ESP32 did you test working fine?

BeFlE commented 4 months ago

Hi,

unfortunately I am not able to compile the firmware for the ESP32-C6. However, it has been tested and provided for the ESP32 and ESP32-C3.

poker-spt commented 4 months ago

@BeFlE Could you please provide the full code for the firmware. Then I could build it for my newer hardware.

BeFlE commented 4 months ago

@poker-spt please write me an E-Mail about this topic.