Command door remote on Aetherwhisp does not work #1837

Open red031000 opened 2 years ago

red031000 commented 2 years ago

Testmerges:

1790

1793

1797

1781

1812

1800

1823

1822

1828

1826

1825

1801

Reproduction:

The command door remote does not work on the aetherwhisp's command doors (specifically unbolting vault and AI chamber does not work through the door remote)

unsure how long this has been an issue, but is an issue now

reproduce by getting the command door remote, set to toggle bolts by clicking on it in hand, then click on the door, nothing happens, bolts are still down

red031000 commented 2 years ago

apologies for lack of round ID, currently unsure and unable to check what ID it was, but is relevant since it was 2 rounds ago as of posting

IndusRobot commented 2 years ago

I was unable to reproduce this issue with the command door remote after successfully opening the vault and AI core. Although the bolt overlays appear to be funny on these vault-type airlocks (see mass airlock megathread issue), their bolt-unbolt action is unaffected by use of the remote.

All I can suggest is, double check that the captain's command door remote is in hand, make sure it's in bolt mode, and double check the area is powered?

IndusRobot commented 2 years ago

Oh I see what's going on now. The door cannot be operated if you're adjacent as it calls the relevant attack proc. It must be operated at least 2 tiles away.