Open penguian opened 3 years ago
@mgk576@nci.org.au commented
Sorry, that was written incorrectly...
diffusivity of water / diffusivity of CO2 at 15 deg is 24 / 15.2 = 1.579 but at the same temperature diffusivity of heat / diffusivity of CO2 is 20.8 / 15.2 = 1.368 not 1.32
At 20 degrees:
diffusivity of water / diffusivity of CO2 = 1.529 diffusivity of heat / diffusivity of CO2 = 1.363
@ccc561@nci.org.au commented
Asking Martin to clarify what the issue is.
@ccc561@nci.org.au set keywords to keepgit
keyword_keepgit
owner:jxs599@nci.org.au
type_defect
| by mgk576CABLE assumes 1.32 for the diffusivity of heat to CO2, this seems to come from (see Bonan table A.3)
This is at 15 deg C.
The diffusivity of stomatal conductance to CO2 in cable = 1.57, which seems to be derived from data at 20 deg C.
See Campbell and Norman table 7.1, the rgbwc term at 20 deg C would be:
Issue migrated from trac:277 at 2023-11-27 11:35:30 +1100