Closed SeanBryan51 closed 4 weeks ago
CABLE tasks are currently failing in the integration test, the PBS log file outputs:
2024-08-29 10:37:36,784 - INFO - benchcab.benchcab.py:352 - 8 failed, 0 passed
Examining the output of a CABLE task shows an error when reading the namelist file:
THE NAME LIST IS cable.nml forrtl: severe (17): syntax error in NAMELIST input, unit 10, file /scratch/tm70/sb8430/benchcab/integration/runs/fluxsite/tasks/AU-Tum_2002-2017_OzFlux_Met_R0_S0/cable.nml, line 25, position 21 Image PC Routine Line Source cable 00000000009D3CBB for__io_return Unknown Unknown cable 0000000000A026CB for_read_seq_nml Unknown Unknown cable 0000000000410C3E Unknown Unknown Unknown cable 000000000040CD62 Unknown Unknown Unknown libc-2.28.so 00001474BDAB57E5 __libc_start_main Unknown Unknown cable 000000000040CC6E Unknown Unknown Unknown
The error points to the check%ranges field. It looks like the test is using an older namelist prior to the check%ranges update.
check%ranges
CABLE tasks are currently failing in the integration test, the PBS log file outputs:
Examining the output of a CABLE task shows an error when reading the namelist file:
The error points to the
check%ranges
field. It looks like the test is using an older namelist prior to thecheck%ranges
update.