Laser 03 - Residue on cut bed mesh - No more 12mm Ply for the time being #6

Closed PancakeLegend closed 5 years ago

PancakeLegend commented 6 years ago

The cutting of 12mm Poplar Ply from Plyco has produced obvious sticky resin residue on the mesh along all cut lines. A method for cleaning the mesh is required. It also produces a significant smoky smell that lingers for days afterward.

I recommend halting the cutting of 12mm Ply on the cutter until a more easily cleaned grid is available.

Should check the filter and I also have concerns for the optics too.

PancakeLegend commented 6 years ago

Mark informs us that the bed mesh material is 303 Stainless and that foaming oven cleaner can be used then washed off to clean the bed.

PancakeLegend commented 5 years ago

Oven cleaner works.